Column AFrequency bandsK=KHz M=MHz G=GHz | Column BType of device | Column CMaximum radiated power of field strength limits & channel spacing | Column DRelevant standard | Column EAdditional requirements |
---|
9-59.75K | Inductive Loop System. | 72 dBμA/m @ 10m.No duty cycle restriction.No channel spacing. | EN 300 330EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
59.75-60.25K | Inductive Loop System. | 42 dBμA/m @ 10m.No restrictions on duty cycleNo channel spacing. | N 300 330EN 301 489-1,3EN 60950ISO/ IEC 18047-2 | CEPT/ERC/REC 70-03ASK, FSK, & PSK |
60.25-70K | inductive Loop System. | 72 dBμA/m @ 10m.No restrictions on duty cycleNo channel spacing. | EN 300 330EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
70-119K | Inductive Loop System. | 42 dBμA/m @ 10m.No restrictions on duty cycleNo channel spacing. | EN 300 330EN 301489-1,3EN 60950ISO/ IEC 18047-2 | CEPT/ERC/REC 70-03ASK FSK, & PSK |
119-135K | Inductive Loop System X | 72 dBμA/m @ 10m.No restrictions on duty cycleNo channel spacing. | EN 300 330EN 301 489-1.3EN 60950ISO/ IEC 18047-2 | CEPT/ERC/REC 70-03ASK, FSK, & PSK |
740-8800K | Inductive Loop System | 9 dBμA/m @ 10m.No restrictions on duty cycleNo channel spacing. | EN 300 330EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
6.765-6.795M | Inductive Loop System | 42 dBμA/m @ 10m.No restrictions on duty cycleNo channel spacing. | EN 300 330EN 301489-1.3EN 60950 | CEPT/EAC/REC 70-03 |
13.553-13.567M | Inductive Loop System | 42 dBμA/m @ 10m.No restrictions on duty cycleNo channel spacing. | EN 300 330EN 301489-1,3EN 60950 | CEPT/ERC/REC 70-03ASK, FSK, & PSK |
26.957-27.283M | Inductive Loop System | 42 dBμA/m @ 10m.No restrictions on duty cycleNo channel spacing. | EN 300 330EN 301489-1,3EN 60950 | CEPT/EAC/REC 70-03 |
26.957-27.283M | Non-specific SRD. | 10mW erpNo restrictions on duty cycle.No channel spacing. | EN 300 220EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
26.995; 27.045;27.095; 27,145;27.195M | Surface Model Control. | 100 mW erp.No restrictions on duty cycle.10 kHz channel spacing. | EN 300 220EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
35.00 - 25.25M | Aircraft Model Control. | 100 mW erp.No restrictions on duty cycle.10 kHz channel spacing. | EN 300 220EN 301489-1,3EN 60950 | CEPT/EAC/REC 70-03 |
36.65 - 36.75M | Wireless Microphones. | 100 mW erp.100% duty cycle.No channel spacing. | EN 300 422EN 301489-9EN 60950 | CEPT/ERC/REC 70-03 |
40.65-40.70M | Wireless Microphones. | 100 mW erp 100%duty cycleNo channel spacing. | EN 300 422EN 301 489-9EN 60950 | CEPT/ERC/REC 70-03 |
40.665, 40.675,40.685, 40.695 | Surface Model Control. | 100mW erp.No restriction on duty cycle.10 kHz channel spacing. | EN 300 220EN 301489-1,3EN 60950 | CEPT/EAC/REC 70-03 |
40.66-40.7M | Non-specific SRD. | 10 mW erp.No duty cycle restriction.No channel spacing. | EN 300 220EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
46.61 - 46.97M49.67 - 49.97M | CTO Cordless Phones. | 10 mW eirp | The Authority TE-013 | Government Gazette 22443 of4th July 2001 |
53-54M | Wireless Microphones. | 50 MW erp for class 1 equipment100 mW erp100% duty cycleNo channel spacing | EN 300 422EN 301 489-1,9 EN 609W | CEPT/ERC/REC 70-03 |
54.4500;54.4625;54.4750;54.4875;54.500;54.5125;54.5250;54.5375;54.5500M | Model Control. | 5W erp12.5kHz channel spacing | EN 300 220EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
141 - 142M | Remote Control Industrial Apparatus. | 100mW erp | EN 300 220EN 301 489-1,3EN 60950 | |
148-152M | Wildlife telemetry Tracking. | 25mW erp | EN 300 220EN 301 489-1,3EN 60950 | The use of this band is restricted to National game Parks |
169.4-169.475M | Meter Reading | 500mW erp50kHz channel spacing< 10% duty cycle | EN 300 220EN 301489-1,3EN 60950 | CEPT/ERC/REC 70-03ECC/DEC (05)02 |
173.2125-173.2375M | Non-specificGRID -telecornrnand only. | 10 mW erp25 kHz channel spacing | EN 300 220EN 301 489-1,3EN 60950 | |
173.2375-173.2875M | Non-specific SRD. | 10 mW erp.25 kHz channel spacing. | EN 300 220EN 301 489-1,3EN 60950 | |
173.965-174.015M | Wireless Microphones and assistivelistening devices. | 2 mW eirp.100% duty cycle.No channel spacing. | EN 300 220EN 301 489-9EN 60950 | CEPT/ERC/REC 70-03 |
402-405M | Medical Implants. | 25 μW erp.No duty cycle restriction for devices with LBT, otherwise≤ 1%.25 kHz channel spacing. | EN 300 839EN 301 489-1,3EN 60950 | ITU-R RS. 1346CEPT/ERC/DEC (01)17 |
402-406M | Doppler shift movement detectors, wireless microphones, garage door openers and motor car alarm systems. | 10 mW erp.No channel spacing.100% duty cycle. | EN 300422EN 300 220EN 301 489-1,3EN 60950 | |
433.05-434.79M | Non specific SRD | 1 SRDW erp.No channel spacing.100% duty cycle | EN 300 220EN 301489-1,3EN 60950ISO/1EC 18047-7 | CEPT/ERC/REC 70-03ASK, FSK, PSK,& FHSS |
433.05-434.79M | Non specific SRD | 10mW erpduty cycle < 10%No channel spacing | EN 300 220EN 301 489-1,3EN 60950ISO/IEC 18047-7 | CEPT/EAC/REC 70-03ASK, FSK, PSK,& FHSS |
433.05-434.79M | Non specific SRD | 10 mW erp100% duty cycleUp to2skHz channel spacing. | EN 300 220EN 301489-3EN 60950ISO/IEC 18047-7 | CEPT/ERC/REC 70-03 |
446 - 446.1Mincludes the following eight channels.446.00625M;446.01875M;446.03125M;446.04375M;446.05625M;446.06875M;446.08125M;446.09375M; | Public Mobile Radio (PMR). | 500mnW.12,5 kHz channel spacing | EN 300 296EN 301 489-5EN 60950 | |
464.5375M | Security systems | 1W25 kHz channel spacing. | EN 300 296EN 301 489-5EN 60950 | |
464.500-464.5875 | Non-specific SRD | 100mWNo channel spacing | EN 300 220EN 301 489-3EN 60950ISO/IEC 18047-7 | |
463.975M;484.125M;464.175M;464.325M;464.375M; | Low Power Radio. | 500mW.12,5 kHz channel spacing | EN 300 296EN 301 489-5EN 60950 | CEPT/ERC/REC 70-03 |
863 - 865M | Wireless Audio Systems. | 10 mW erp.100% duty cycle.No channel spacing. | EN 300 357EN 301 489-9EN 60950 | CEPT/ERC/REC 70-03CEPT/EAC/DEC (01)18 |
863 - 865M | Wireless Microphones | 10 mW erp.100% duty cycle.No channel spacing. | EN 300 422EN 301 489-9EN 60950 | CEPT/ERC/REC 70-03 |
864.1 - 868.1M | CT2 cordless telephones | 10 mW eirp. | EN 301 797EN 301489-1,10The Authority TE-012 | CEPT/EAC/REC 70-03 |
868 - 868.6M | Non specific SRD | 25 mW erp.< 1% duty cycle or LBT. | EN 300 220EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03CEPT/ERC/DEC(01) 04 |
868.6 -868.7M | Alarms. | 10mW erp.< 1% duty cycle.25 kHz channel spacing. | EN 300 220EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03CEPT/ERC/REC(01) 09 |
888.7-869.2M | Non specific SRD | 25 mW erp.< 0.1% duty cycle or LBT.No channel spacing. | EN 300 220EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03CEPT/EAC/REC(01) 04 |
869.25-869.3M | Alarms. | 10 mW erp.< 0.1 % duty cycle.25 kHz channel spacing. | EN 300 220EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
869.4 - 869.65M | Non-specific SRD. | 500mW erp.< 10% duty cycleor LBT.25 kHz channel spacing. | EN 300 220EN 301 489-1,3EN 60950 | CEPT/EAC/REC 70-03 |
869.65 - 869.7M | Alarms | 25 mW erp.10% duty cycle.25 kHz channel spacing. | EN 300 220EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
869.7-870.0M | Non-specific SRD. | 5 mW erp.100% duty cycle.No channel spacing. | EN 300 220EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
1880 - 1900M | DECT cordless phones. | 250 mW eirp (peak).1.728 MHzchannel spacing. | EN 300 406EN 301489-1,6EN 60950The Authority TE 001 | |
2400-2483.5M | Non-specific SRD | 10 MW erp. No duty cycle.No channel spacing. | EN 300 440EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
2400 - 2483.5M | Wideband Wireless SystemsWLANWideband Data Transmission Applications (WBDTS)Model Control | 100 mW eirp. No duty Cycle.No channel spacing. | EN 300 328EN 301 489 -1,3EN 60950 | CEPT/ERC/REC 70-03 |
2400 - 2483.5M | FDDA | 25 mW erp. No duty cycle.No channel spacing. | EN 300 440EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
2400-****2483.5M | Low power Video Surveillance | 100 mW erp. No duty cycle.No channel spacing. | EN 300 440EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
5150 - 5350M | Wireless Access Systems / Radio Local Access Network WAS & RLAN) indoor use only. | 200 MW eirp.Dynamic Frequency Selection (DFS)& Transmitter Power Control Obligatory. | EN 300 893EN 301 489-1,17EN 60950 | ITU-RM.1625 |
5470-5725M | Wireless Access Systems / Radio Local Access Network (WAS& RLAN): indoor use only. | 1 W eirp.Dynamic Frequency Selection (DFS)& Transmitter Power Control Obligatory. | EN 300 893EN 301 489-1,17EN 60950 | ITU-R M.1625 |
5725 - 5875M | | 1 watt peak eirpAny modulation | | |
5725 - 5875M | | 4 watt peak eirpFrequency hopping or digital modulation only | | |
5795-5805M | RTTT data | 2 W eirp.No duty cycle restriction.No channel spacing. | EN 300 674EN 301 489-1,3EN 60950 | ITU-R M,1 453CEPT/ERC/DEC (92)02 |
5805-5815M | RTTT data. | 2W eirp.No duty cycle restriction.No channel spacing. | EN 300 674EN 301 489-1,3EN 60950 | ITU-R M.1453CEPT/ERC/DEC (92)02 |
9200-9500M | FDDA. | 25 mW eirp.No duty cycle restriction.No channel spacing. | EN 300 440EN 301 489-1,3EN 60950 | CEPT/EAC/REC 70-03 |
9500-9975M | FDDA. | 25 mW eirp.No duty cycle restriction.No channel spacing. | EN 300 440EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
10.5 -10.6G | FDDA. | 500 MW eirp.No duty cycle restriction.No channel spacing. | EN 300 440EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
13.4 -14G | FODA. | 25 mW eirp.No duty cycle restriction.No channel spacing. | EN 300 440EN 301 489-1.3EN 60950 | CEPT/ERC/REC 70-03 |
17.1 -17.3G | Wireless Access Systems / Radio Local Access Network (WAS & RLAN). | 100 mW eirp. | EN 300 440EN 301489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
24.00-24.25G | Non-specific SRD. | 100 MW eirp.No duty cycle restriction.No channel spacing. | EN 300 440EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
24.05 - 24.25G | FDDA. | 100 mW eirp.No duty cycle restriction.No channel spacing. | EN 300 4.40EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |
76-77G | RTTT radar | 55dBm peakNo duty cycle restrictionNo channel spacing | EN 300 091EN 301 489-1,3EN 60950 | CEPT/ERC/REC 70-03 |